Порівняльний аналіз експериментальних та результатів імітаційного моделювання роботи автономної вітроелектричної установки з асинхронним генератором з використанням імпульсного пристрою для зарядження акумуляторних батарей
Анотація
COMPARATIVE ANALYSIS OF EXPERIMENTAL AND SIMULATION OF THE AUTONOMOUS simulation of wind power installations with asynchronous generators USING PULSE device for charging batteries
V. M. Golovko, K. R. Sandoval
The use of autonomous systems with asynchronous wind generator for its simplicity of design, high reliability is one of the efficient ways for remote power supply from the central system users. Using asynchronous machine as generator reactive power demands submission to the stator winding for self-excitation, which is often made from block capacitors.
The aim of study was a comparative analysis of the efficiency of wind power battery systems with asynchronous generator and pulse converter for charging batteries on indicators obtained on the basis of simulation and experiment.
For this experimental stand was developed, consisting of the following elements: wind power plant with an asynchronous generator, three-phase rectifier pulse converter and the load (battery). Control switching key by using pulse-width modulation with an operating frequency of 2 to 10 Hz.
The research program was supposed to determine the influence of the pulse duty cycle of the converter weekend performance induction generator wind turbines at different wind speeds below par in the range of 0.95 to 0.75 /
The analysis shows that the change in duty cycle of 0.2 to 0.9 asynchronous machine loses generator mode by changing wind speeds in the range of 0.95 - 0.75 of the nominal value. The discrepancy between the values obtained by experiment and model, is between 3 and 5%, indicating its adequacy.
Повний текст:
PDFПосилання
Krivtsov, V. S., Oleynikov, A.M. , Yakovlev, A.I. (2003). Neischerpemaya energiya. Kn. 1. Vetroeyeletrogeneratory [Inexhaustible energy. Book. 1. Wind turbine generators]. Khar’kov: Nats. Aerokosmyu un-t «KHar’k. aviats. in-t», Sevast., 400.
Mkhitaryan, N. M., Kudrya, S. A., Perminov, Y. N., Budennyy, V. F. (2010). Analiz nekotorykh osobennostey sinkhronnykh i asinkhronnykh generatorov, ispol’zuyemykh v kachestve avtonomnykh istochnikov energii [Analysis of some features of synchronous and asynchronous generators used as autonomous energy sources]. Vіdnovlyuv. Energetika, № 2, 7-9.
Golovko, V.M., Kokhanevich, V. P., Shikhaylov, N. A. and etc. (2017). Imitatsionnaya model’ dlya analiza parametrov avtonomnykh vetroelektricheskikh ustanovok s asinkhronnym generatorom [Simulation model for analysis of parameters of autonomous wind power plants with an asynchronous generator]. Al’ternativnaya energetika i ekologiya (ISJAEE), (4-6):42-52. DOI:10.15518/isjaee.2017.04-06.042-052.
Bryl’, A. A., Vas’ko, P. F., Pekur, P.P. (1992) Sistema generirovaniya elektricheskoy energii na osnove asinkhronnykh mashin s korotkozamknutym rotorom dlya avtonomnykh vetroelektricheskikh ustanovok [Electric power generation system based on squirrel cage asynchronous machines for autonomous wind power plants]. Reguliruyemyye asinkhronnyye dvigateli: sb. nauch. trudov. Kyiv: In-t elektrodinamiki AN Ukrainy, 39-44.
Barrado, J. A., Grino, R. (2006). Voltage and Frequency Control for a Self-Excited Induction Generator Using a Three-Phase Four-Wire Electronic Converter. 12th International Power Electronics and Motion Control Conference, Portoroz,. 1419-1424. doi: 10.1109/EPEPEMC.2006.4778602.
Vellapatchi Nayanar, Natarajan Kumaresan. (2016). Wind-driven Seig supplying DC microgrid through a single-stage power converter / Engineering Science and Technology, an International Journal.
Hammadi, S., Hidouri, N.,Sbita, L. (2013). A DTC SEIG drive scheme for an isolated wind turbine buck system. International Conference on Control, Decision and Information Technologies (CoDIT), Hammamet, 543-548.
Kudria, S. O., Budko, V. I. , Pavlov, V. B., Popov, A. V. Pavlenko, V. Ie. (2010). Doslidzhennia roboty zariadnoho prystroiu akumuliatornoi batarei vid vitroahrehatu [Study of the battery charger from the wind turbine]. Vidnovliuv. Enerhetyka, 4, 5-10.
Метрики статей
Metrics powered by PLOS ALM
Посилання
- Поки немає зовнішніх посилань.