Frequency-regulated start of an asynchronous electric drive of a pumping system powered by a standalone photovoltaic source of commensurate capacity

Authors

  • V. Golovko National Technical University of Ukraine “Igor Sikorsky Kyiv Polytechnic Institute”
  • R. Semenenko National Technical University of Ukraine “Igor Sikorsky Kyiv Polytechnic Institute”

DOI:

https://doi.org/10.31548/energiya5(87).2026.075

Keywords:

standalone photovoltaic system, centrifugal pump, induction motor drive, frequency-controlled starting, mathematical modeling

Abstract

Implementation of a variable frequency drive in autonomous photovoltaic pumping systems is a critical task for minimizing starting overloads and ensuring stable operation of an autonomous power supply.

Purpose and Objectives. Development and verification of a mathematical model describing the behavior of current and active power during frequency-controlled starting of a centrifugal pump induction motor under autonomous power supply conditions.

Methods. Tests were conducted on a custom laboratory experimental bench consisting of a LiFePO4 battery pack (26.4 V, 105 Ah), a 3.5 kW Fchao inverter, an INVT GD10 frequency converter, a 1.5 kW induction motor, and a centrifugal pump. Fast transient processes were recorded using a Hantek 6022BE oscilloscope via ACS758 and ZMPT101B sensors. Mathematical processing, 4th-order zero-phase Butterworth digital filtering (filtfilt), and sliding RMS calculations were performed in the MATLAB environment.

Results and Conclusions. A piecewise-continuous current and power model was developed, taking into account non-linear pump load characteristics (power coefficients , ). Experiments in 9 matrix modes ( Hz,  s) confirmed high accuracy of the model with a maximum coefficient of determination  for current and  for active power. Frequency-controlled starting at  s eliminates starting inrush current surges and limits inverter voltage sag to 2–4 V. The mode with an acceleration ramp of  s at operating frequencies of 40–50 Hz was determined to be optimal.

Received: 28.07.2026. Revised: 12.09.2026. Accepted: 16.10.2026.

References

1. Rehman S., Al-Hadhrami L. M., Alam M. M. (2015). Pumped hydro energy storage system: A review for renewable energy integration. Renewable and Sustainable Energy Reviews, 44, 586–598. DOI: 10.1016/j.rser.2014.12.056 (Scopus)

2. Campana P. E., Li H., Zhang J., Zhang R., Yan J. (2013). Dynamic modelling and performance analysis of photovoltaic water pumping systems. Applied Energy, 111, 1172–1181. DOI: 10.1016/j.apenergy.2013.04.020 (Scopus)

3. Preger Y., Barkholtz H. M., Fresquez A., Campbell D. L., Jinson H. (2020). Degradation and Failure Modes in Lithium-Ion and Lithium Iron Phosphate Batteries Under Peak Loads. Journal of The Electrochemical Society, 167 (12). Art. 120532. DOI: 10.1149/1945-7111/abae37 (Scopus)

4. Ostroverkhov M. Ya., Burian S. O. (2020). Control of frequency-controlled induction motor drives in special modes: monograph. Kyiv: Igor Sikorsky Kyiv Polytechnic Institute,. 184.

5. Bakir H., Kulaksiz A. A. (2017). Modelling and performance analysis of a V/f controlled induction motor drive for solar water pumping applications. Energy Conversion and Management,. 152, 182–193. DOI: 10.1016/j.enconman.2017.09.034 (Scopus)

6. Chicco D., Warrens M. J., Jurman G. (2021). The coefficient of determination R-squared is more informative than SMAPE, MAE, MAPE, MSE and RMSE in regression analysis evaluation. PeerJ Computer Science, 7. Art. e623. DOI: 10.7717/peerj-cs.623

7. Kovalenko O. I., Sydorenko V. M., Tkachenko P. P. et al. (2023). Research of autonomous power systems based on solar power plants and closed-loop micro-PSH. Vidnovlyuvana Energetyka, 2 (73), 45–53. https://doi.org/10.36296/1819-8058.2023.2.45-53

8. Melnyk D. V., Shevchenko A. S. (2022). Mathematical modeling of pumping units with frequency-controlled drives as part of photovoltaic systems. Transactions of the Institute of Electrodynamics of the National Academy of Sciences of Ukraine. 2022. Issue 61. P. 88–95. https://doi.org/10.15407/ied2022.61.088

9. Golovko V., & Semenenko R. (2024). Analysis of the closed-cycle pumped-storage hydroelectric power stations. Vidnovluvana Energetika, 1(76), 89–100. https://doi.org/10.36296/1819-8058.2024.1(76).89-100

10. Golovko V., & Semenenko R. (2026). Improvement of the method for matching characteristics of the pump of a pumped storage system and a photovoltaic station. Vidnovluvana Energetika, 1(84), 55–76. https://doi.org/10.36296/1819-8058.2026.1(84).55-76

11. Bondarenko I. V., Hlushko O. M. (2024). Transient processes during starting of induction motors of pumping units from autonomous inverters of limited power. Energy: Engineering, Automation, Energy Efficiency. 2024. No. 1. P. 112–121. https://doi.org/10.31548/energetiya2024.01.112

12. Serhiienko A. B. (2011). Digital signal processing: textbook. Kyiv: Publishing and Printing Centre "Kyiv University", 416.

13. Oppenheim A. V., Schafer R. W. (2009). Discrete-Time Signal Processing. 3rd ed. Upper Saddle River, NJ: Prentice Hall, 1120.

14. Butterworth filter design (butter). MATLAB Signal Processing Toolbox Documentation. Natick, MA: The MathWorks, Inc., 2024. URL: https://www.mathworks.com/help/signal/ref/butter.html (date of access: 29.08.2026).

15. Zero-phase digital filtering (filtfilt). MATLAB Signal Processing Toolbox Documentation. Natick, MA: The MathWorks, Inc., 2024. URL: https://www.mathworks.com/help/signal/ref/filtfilt.html (date of access: 29.08.2026).

16. Babak V. P., Zaporozhets O. I., Filonenko S. F. (2014). Signal processing in diagnostic systems: textbook. Kyiv: Publishing and Printing Centre "Kyiv University",. 384.

17. Popovych M. H., Kozyreva O. V. (2018). Theory of automatic control of electric drives: textbook. Kyiv: Igor Sikorsky Kyiv Polytechnic Institute, 240.

18. Zahirniak M. V., Kalynov A. P., Kostenko O. V. (2018). Evaluation of energy performance of an induction motor as part of a frequency-controlled pumping unit. Transactions of the Institute of Electrodynamics of the National Academy of Sciences of Ukraine, 50, 68–74.

19. Montgomery D. C., Peck E. A., Vining G. G. (2021). Introduction to Linear Regression Analysis. 6th ed. Hoboken, NJ: John Wiley & Sons, 672.

Published

2026-10-31

Issue

Section

Статті

How to Cite

Golovko, V., & Semenenko, R. (2026). Frequency-regulated start of an asynchronous electric drive of a pumping system powered by a standalone photovoltaic source of commensurate capacity. Energy and Automation, 5, 75-87. https://doi.org/10.31548/energiya5(87).2026.075