Modelling of a pumping unit as a multidomain electrical system using the bond-graph method

Authors

  • P. Kurliak Ivano-Frankivsk National Technical University of Oil and Gas image/svg+xml
  • O. Chornyi Kremenchuk Mykhailo Ostrohradskyi National University image/svg+xml
  • V. Pavlenko National University of Life and Environmental Sciences of Ukraine image/svg+xml
  • V. Lyktei National University of Life and Environmental Sciences of Ukraine image/svg+xml
  • H. Kruhliak National University of Life and Environmental Sciences of Ukraine image/svg+xml

DOI:

https://doi.org/10.31548/energiya5(87).2026.106

Keywords:

multi-domain modelling, Bond Graph, asynchronous motor, centrifugal pump, start-up modes, shut-off valves, relay protection

Abstract

Oil pumping stations on main oil pipelines are complex electrical engineering systems in which electrical, mechanical and hydraulic processes are closely interrelated; therefore, a reliable analysis of their transient modes requires multi-domain models. The aim of the study is to develop a computer-based multi-domain model of an electrically driven main pipeline pump unit and to investigate its start-up modes under various valve configurations. The physically-based Bond Graph method, electro-hydraulic analogy, simulation modelling in the 20-sim environment and experimental verification at the «Pleshchivka» pumping station on the «Druzhba» oil pipeline were employed. A Bond Graph model of the «4AZMV-2500/6000 asynchronous motor – NGK-500-450-100 centrifugal pump» unit was synthesised, supplemented by sub-models of the non-return valve and the discharge gate valve. Calculations of the relay protection system confirmed that the starting currents when the gate valve is open do not cause the protection systems to trip. The developed model is suitable for predicting transient processes and selecting optimal starting modes.

Received: 16.07.2026. Revised: 15.09.2026. Accepted: 16.10.2026.

References

1. Chaudhry, M. H. (2014). Applied hydraulic transients (3rd ed.). Springer. https://doi.org/10.1007/978-1-4614-8538-4

2. Misiunas, D. (2004). Burst detection and location in pipelines by transient analysis [Doctoral thesis, Lund University]. http://www.iea.lth.se/publications/Theses/LTH-IEA-1038.pdf

3. Oseni, W. Y., Akangbe, O. A., & Abhulimen, K. (2023). An integrated Neuro-Fuzzy approach for pipeline leak detection and localization. Heliyon, 9(4), e15412. https://doi.org/10.1016/j.heliyon.2023.e15412

4. Ahmed, S., Le Mouël, F., Stouls, N., & Lipeme Kouyi, G. (2023). Toward an IoT-cloud-based smart water pipeline monitoring system. Sensors, 23(9), 4298. https://doi.org/10.3390/s23094298

5. Zhang, X., et al. (2023). Pipeline leakage detection methods and their applicability. Process Safety and Environmental Protection, 174, 460–472. https://doi.org/10.1016/j.psep.2023.04.020

6. Kallesoe, C. S., Cocquempot, V., & Izadi-Zamanabadi, R. (2006). Model based fault detection in a centrifugal pump application. IEEE Transactions on Control Systems Technology, 14(2), 204–215.

7. Kallesoe, C. S., et al. (2004). Adaptive friction compensation in a hydraulic system. In Proceedings of the IEEE International Conference on Control Applications (Vol. 2, pp. 1229–1235). IEEE.

8. Miedema, S. A. (1996). Modeling and simulation of dredge pump systems. Paper presented at the 17th Annual Meeting of the Western Dredging Association (WEDA), New Orleans.

9. Kiselychnyk, O., Burian, S., & Pushkar, M. (2009). Matematychna model naosu z urakhuvanniam prostorovoho rozpodilu truboprovodu [Mathematical model of a pump considering the spatial distribution of the pipeline]. In Suchasni problemy elektroenerhotekhniki ta avtomatyky: materialy Mizhnar. nauk.-tekhn. konf. molodykh uchenykh, aspirantiv, studentiv (Vol. 2, pp. 23–26). Kyiv: Politekhnika.

10. Kutsyk, A. S., Lozynskyi, A. O., & Kinchur, O. F. (2015). Matematychna model asynchronnoho dvyhuna [Mathematical model of an induction motor]. Visnyk Natsionalnoho universytetu «Lvivska politekhnika», (834), 48–55.

11. Orlovskis, G., & Ketners, K. (2013). Transient processes in pump drive systems. Power and Electrical Engineering, 31, 117–122.

12. Vasquez, H., & Parker, J. K. (2004). A nonlinear model for hydraulic pipeline systems. Mechatronics, 14(9), 1055–1068.

13. Omri, F., Hadj Taieb, L., & Elaoud, S. (2021). Water hammer in pipeline systems with pumps. AQUA — Water Infrastructure, Ecosystems and Society, 70(3), 257–273.

14. Lysiak, V. H., & Oliinyk, M. Y. (2021). Identyfikatsiia parametriv nasosnykh ahrehativ [Identification of pump unit parameters]. Visnyk Pryazovskoho derzhavnoho tekhnichnoho universytetu, (42), 113–121. https://doi.org/10.31498/2225-6733.42.2021.240665

15. Podchasynsky, Yu. O., & Mahaletsky, Ya. V. (2026). Modeliuvannia elektromekhanichnykh system [Modeling of electromechanical systems]. Tekhnichna inzheneriia, (1(97)), 365–371. https://doi.org/10.26642/ten-2026-1(97)-365-371

16. Kostyshyn, V. S. (2000). Modeliuvannia rezhymiv roboty vidtsentrovykh nasosiv na osnovi teorii elektrychnykh kil [Modeling of centrifugal pump operating modes based on the theory of electrical circuits]. Fakel.

17. Kostyshyn, V. S., Yaremak, I. I., & Kurliak, P. O. (2019). Matematychne modeliuvannia nasosnykh ahrehativ metodom Bond Graph [Mathematical modeling of pump units using Bond Graph method]. Naukovyi visnyk Natsionalnoho hirnychoho universytetu, (6), 72–79. https://doi.org/10.29202/nvngu/2019-6/11

18. Borutzky, W. (2021). Bond graph modelling for control, fault diagnosis and failure prognosis. Springer. https://doi.org/10.1007/978-3-030-60967-2

19. Karnopp, D. C., Margolis, D. L., & Rosenberg, R. C. (2012). System dynamics: Modeling, simulation, and control of mechatronic systems (5th ed.). Wiley. https://doi.org/10.1002/9781118152812

20. Controllab Products. (n.d.). 20-sim simulation software. Retrieved October 28, 2026, from https://www.controllab.nl/technology/software/20-sim/

21. Kurliak, P. O. (2011). Matematychna model nasosnykh ahrehativ metodom Bond Graph [Mathematical model of pump units using Bond Graph method]. Naukovi pratsi Donetskoho natsionalnoho tekhnichnoho universytetu, (11(186)), 221–225.

22. Kostyshyn, V. S., & Kurliak, P. O. (2012). Bond Graph model vidtsentrovoho nasosa [Bond Graph model of a centrifugal pump]. Visnyk Vinnytskoho politekhnichnoho instytutu, (2), 148–153.

Published

2026-10-31

Issue

Section

Статті

How to Cite

Kurliak, P., Chornyi, O., Pavlenko, V., Lyktei, V., & Kruhliak, H. (2026). Modelling of a pumping unit as a multidomain electrical system using the bond-graph method. Energy and Automation, 5, 106-117. https://doi.org/10.31548/energiya5(87).2026.106