FEATURES OF PREPARATION OF SAMPLES FOR DIAGNOSTICS OF BOVINE LEUKOSISUSING THE IMMUNE BIOSENSOR

Автор(и)

  • M. F. Starodub
  • M. V. Savchuk
  • M. I. Fedelesh-Gladinets
  • O. P. Taran

DOI:

https://doi.org/10.31548/biologiya2018.287.136

Анотація

The article discusses the best options for the preparation of blood and milk samples for the purpose of diagnosing retroviral  enzootic bovine leukosis in cattle and assessing the origin of dairy products from sick or healthy animals. The effectiveness of using samples in the native state and after their processing with the removal of red blood cells, their membranes, the fat component and casein were analyzed. It has been established that when performing screening analysis it can be carried out using whole blood and milk samples. This is especially possible in the case of diagnosis of the disease at the stage of its progressive development. The use of such samples significantly reduces analysis time and makes it simpler. But if it is necessary to carry out data verification and detection of cattle retroviral leukemia virus already in the early periods, then, in accordance with the results obtained by us, samples prepared in the form of blood serum or milk serum should be used. The latter should also be used to accurately assess the origin of milk, especially when it is necessary to control its quality when collecting from several animals, among which may be sick individuals, as well as in the early stages of the development of the pathological process.

Посилання

Kurtinaitiene, B. Ambrozaite, D. Laurinavicius, V. Ramanaviciene, A. Ramanavicius, A. (2008). Amperometric immunosensor for diagnosis of BLV infection, Biosens. Bioelectron. 23, 1547-1554.

https://doi.org/10.1016/j.bios.2008.01.014

Kirkland, P. D. (2005). Enzootic bovine leukosis, Aust. New Zeal. Stand. Diagnostic Proced. 1-14.

Hassanpour, M., Nadalian, M., Safi, S. Madani, R., Bokaie, S. (2014). Epidemiological survey of Bovine Leukemia Virus (BLV) infection and its effective factors emphasis ELISA and nested PCR in dairy herds around Babol city (North of Iran) as a Caspian climate.Eur. J. Zool. Res. 3, 166-171.

Balić, D., I., Lojkić, M. Periškić, T. Bedeković, A. Jungić, N. Lemo, B. Roić, Ž. Čač, L. Barbić, J. (2012). Madić, Identification of a new genotype of bovine leukemia virus, Arch. Virol, 157, Р. 1281-1290.

https://doi.org/10.1007/s00705-012-1300-4

Choudhury, B., Finnegan, C., Frossard, J. P., Venables, C., Steinbach, F. (2013). Colostrum replacer and bovine leukemia virus seropositivity in calves, Emerg. Infect. Dis, 19, 1027-1028.

https://doi.org/10.3201/eid1906.121523

S chwartz, I., Levy, D. (1994). Pathobiology of bovine leukemia virus, Vet Res. 25, 521-536.

Ramanaviciene, A., German, N., Kausaite-Minkstimiene, A., Voronovic, J., Kirlyte, J., Ramanavicius, A. (2012). Comparative study of surface plasmon resonance, electrochemical and electroassisted chemiluminescence methods based immunosensor for the determination of antibodies against human growth hormone, Biosens. Bioelectron, 36, 48-55.

https://doi.org/10.1016/j.bios.2012.03.036

B aniukevic, J., Kirlyte, J., Ramanavicius, A., Ramanaviciene, A. (2013). Application of oriented and random antibody immobilization methods in immunosensor design, Sensors Actuators, B Chem, 189, 217-223.

https://doi.org/10.1016/j.snb.2013.03.126

Balevicius, Z., Ramanaviciene, A., Baleviciute, I., Makaraviciute, A., Mikoliunaite, L., Ramanavicius, A. (2011). Evaluation of intact- and fragmented-antibody based immunosensors by total internal reflection ellipsometry, Sensors Actuators, B Chem, 160, 555-562.

https://doi.org/10.1016/j.snb.2011.08.029

Makaraviciute, A., Ruzgas, T., Ramanavicius, A., Ramanaviciene, A. (2014). Antibody fragment immobilization on planar gold and gold nanoparticle modified quartz crystal microbalance with dissipation sensor surfaces for immunosensor applications, Anal. Methods, 6, 2134-2140.

https://doi.org/10.1039/C4AY00070F

Ramanavicius, A., Finkelsteinas, A., Cesiulis, H., Ramanaviciene, A. (2010). Electrochemical impedance spectroscopy of polypyrrole based electrochemical immunosensor, Bioelectrochemistry,. 7, 11-16.

https://doi.org/10.1016/j.bioelechem.2009.09.013

Ramanavicius, A., Oztekin, Y., Ramanaviciene, A. (2014). Electrochemical formation of polypyrrole-based layer for immunosensor design, Sensors Actuators, B Chem, 197, 237-243.

https://doi.org/10.1016/j.snb.2014.02.072

Viter, R., Starodub, N., Smyntyna, V., Tereschenko, A., Kusevitch, Sitnik, J., Buk, J., Macakd, J. (2011). Immune biosensor based on silica nanotube hydrogels for rapid biochemical diagnostics of bovine retroviral Leukemia, Procedia Eng, 25, 948-951.

https://doi.org/10.1016/j.proeng.2011.12.233

Pyrohova, L. V. Starodub, M. F. (2008). Immobilizatsiia antyhenu retrovirusu immobilizatsiia antyhenu retrovirusu leikozu velykoi rohatoi khudoby leikozu velykoi rohatoi khudoby na poverkhni imunnoho biosensora na poverkhni imunnoho biosensora. Biotekhnolohiia, 1(2), 1-75.

Pyrohova, L. V., Starodub, M. F. (2002). Immobilizatsiia imunohlobuliniv za dopomohoiu lektyniv pry stvorenni imunnykh sensoriv na osnovi poverkh nevoho plazmonnoho rezonansu. Ukr. biokhim. Zhurn, 74 (2), 45-50.

Starodub, M. F., Starodub, V. M. (2002). Biosensory: vytoky, dosiahnennia i perspektyvy. Ukr. biokhim. Zhurn, 74(4-5), 147-163.

##submission.downloads##

Опубліковано

2018-11-16

Номер

Розділ

Статті